Roof diagrams
install cheat sheet: color / b&w
The small dormer modules will be on rails.
Phase-1 diagram here
Stock
Click item to go to webpage.
| group | item | count |
|---|---|---|
| rack | s-5 - pvkit 2.0 mid-grab (spec) | 1 |
| rack | s-5 - pvkit 2.0 edge-grab (spec) | 1 |
| pv module | auxin - 440w (spec) | 28 |
| rsd | tigo - ts4 optimizer + rapid shutoff (spec) | 20 |
| inverter | sma - 9.6k SBSE9.6-US-50 (spec) | 1 |
| ac battery | franklin - a-power s (spec) | 1 |
| ac battery | franklin - a-power 2 (spec) | 1 |
| mid | sma - backup select (spec) | 1 |
| mid | franklin - a-gate x (spec) | 1 |
| black start | sma - backup start (spec) | 1 |
| heat pump | eg4 - solar ac / dc 24k mini-split (spec) | 4 |
Math
S unit
Between 4 and 14 Auxin 440s per mppt (4 mppts).
Min: hot roof, the voltage sags
Vmp,hot = 33.4 V × (1 − 0.161%/°F × (167°F − 77°F)) ≈ 28.5 V
n_min = ⌈ 90 V ÷ 28.5 V ⌉ = ⌈3.16⌉ = 4
Max: cold morning (30°F design low), the voltage climbs
Voc,cold = 39.6 V × (1 + 0.139%/°F × (77°F − 30°F)) ≈ 42.2 V
n_max = ⌊ 600 V ÷ 42.2 V ⌋ = ⌊14.2⌋ = 14
Power: 4 strings (1, 2, 5, 6 on the strings diagram)
P_string = 14 × 440 W = 6.16 kW stc (string 5; clips at 5 kW per input)
P_total = 46 × 440 W = 20.24 kW stc (0.24 kW over the 20 kW max)
Mini-split
Between 4 and 9 Auxin 440s per mini-split.
Min: hot roof, the voltage sags
Vmp,hot = 33.4 V × (1 − 0.161%/°F × (167°F − 77°F)) ≈ 28.5 V
n_min = ⌈ 90 V ÷ 28.5 V ⌉ = ⌈3.16⌉ = 4
Max: cold morning (30°F design low), the voltage climbs
Voc,cold = 39.6 V × (1 + 0.139%/°F × (77°F − 30°F)) ≈ 42.2 V
n_max = ⌊ 380 V ÷ 42.2 V ⌋ = ⌊9.00⌋ = 9
Module cells at 167°F on a hot roof, 77°F test conditions, a 30°F design low (mean of each year's coldest morning). At the 18°F record low, 14 in series reaches 600 V, right at the S unit's limit. 9 reaches 386 V, over the mini-split's 380 V. This job's mini-split string is 7 (300 V at the record low). The S unit tracks 90 to 480 V dc (600 V max), the mini-split 90 to 380 V dc.